Modbus Poll, reimagined — in pure Rust.
A clean-room Modbus Poll reimplementation with a SCADA mode on top.
Poll Modbus/TCP & RTU devices into live value tables, import real Modbus Poll .mbp/.mbw files byte-exactly,
style any row from a 32-branch rule tree and build mimic diagrams —
all in a ~6 MB single executable. No Modbus Poll sources were read, ever.
English · Русский 🌐 Project site: kostyk348.github.io/mbscada-rs
🧭 TL;DR
- 🖥 Modbus Poll, but better. Polls 01/02/03/04, writes 05/06/0F/10, per-poll slave / base-0·1 address / scaling / engineering units — and every connection gets a live traffic log with per-response turnaround.
- 🤝 Drop-in for your existing configs. Real Modbus Poll
.mbp/.mbwfiles import by folder — and a byte-exact round-trip layer (write(parse(bytes)) == bytes, proven on real 10.5 files) keeps them intact. - 🎨 32 styled branches per row. The original gives you two colour rules; here every row gets a first-match rule tree with per-branch dynamic row text («0 → Закрыт, 1 → Открыт»).
- 📈 Trends, alarms, CSV. Per-row sparklines, hi/hi‑hi/lo/lo‑lo alarms, blink styles — and a one-click CSV value log.
- 👁 Parameter watch window. Pin the registers you actually watch — or computed tags — into a floating window with big live values, alarm colours and session min/max (v1.2).
- 🧪 Slave simulator + typed values. The app can answer as a Modbus device — poll it with any master (or with itself): editable register grid, sine/ramp/noise auto-generation, TCP, RTU-over-TCP and — since v1.4 — a physical COM/RS-485 line (USB-RS485 adapter, 9600 8E1 and friends; line garbage never wedges the slave). Values display and write as real / int / uint mixed — float32/64 with all four word orders, 32/64-bit ints, hex/bin — with typed write modals and a per-cell dec → hex → bin display cycle (v1.3).
- 🧮 Computed tags. Arithmetic on your tags —
{T2 jacket} - {T1 reactor},min(...),pow(...)— evaluated by the engine every scan and shown in their own table (v1.1). - 🗄 Journal + archive + diagnostics. Engine events (RX/WR/ERR/SYS) appended to a log file, configurable CSV historian (change-only or interval mode), per-connection/per-poll diagnostics with reconnect counters (v1.1).
- 🌐 RU/EN built in. One switch in the toolbar flips the entire UI; docs ship in both languages.
- ⚡ Fast & local. A multithreaded engine (
mb-engine) drives all connections concurrently; no telemetry, no cloud, nothing leaves the machine. - 🎓 Tutorial + demo project. An interactive tour that highlights real UI elements and auto-advances once you've done the step — plus a "🚀 Demo project" button: the app raises its own slave simulator and polls itself, so live tables, rules, a computed tag and a dressed-up mimic come alive in 10 seconds (v1.5).
- 🎛 Rules on the mimic + new widgets. Lamps, gauges, bars and values are colored by the fired rule branch (color/text/blink) — exactly like table rows; the "State" widget shows the branch text ("OPEN/CLOSED"), trends plot the history with min/max spans, sliders write a value into a register, computed tags became a widget source, and a "Rule for register…" button sits right in the widget settings (v1.5).
⬇ Download v1.7.0
Prebuilt installers for every platform — no Rust toolchain needed. Grab them from Releases:
| Platform | Files |
|---|---|
| Windows 10/11 x64 | NSIS installer .exe · .msi · portable zip (no install) |
| Linux x86_64 & aarch64 | .AppImage (runs anywhere — already no-install) · .deb |
| macOS Apple Silicon & Intel | .dmg · portable zip with the .app bundle |
OPC UA bridge mb-opc |
mb-opc-linux-x64 / -arm64 · mb-opc-windows-x64.exe · mb-opc-macos-arm64 (same release page) |
Windows: WebView2 is preinstalled on Win10/11. Linux AppImage bundles its own WebKit. Every release is built automatically by GitHub Actions from a
v*tag — five runners, one commit, all platforms.
✨ Feature tour
📊 Live tables
- Every poll is an independent view of the address space: own function, own register window, own scaling
×mult ÷div +offset, own 0/1 address base. - Values render in Modbus-Poll-style formats:
u16 / i16 / hex16 / bin16 / ascii16 / u16(swapped)·u32 / i32 / hex32·float32in word orders ABCD / CDAB / BADC / DCBA · 64-bitu64 / i64 / f64. - Per-row sparklines keep the last 40 samples as inline SVG — the last buffer change blinks.
- Click a row to write a value (FC 05/06 for bits, FC 16 for word arrays).
🚦 Rules & alarms
- Threshold alarms exactly like Modbus Poll: hi / hi‑hi / lo / lo‑lo with messages.
- Styling rules with up to 32 branches per row and operators
> ≥ < ≤ = ≠, in-range / out-of-range, bit test. - First matching branch wins — the classic «Rule 1 over Rule 2» becomes a full priority list.
- Dynamic row text per branch: the row label is replaced when a branch fires (state machines live in the table header).
- Alarm side panel: active alarms surface as cards — severity, fired-at, live value, message — acknowledge one or all, cleared alarms drop to history with durations, optional beep, and a click jumps to the table row.
👁 Parameter watch window (v1.2)
- Pin the parameters you actually watch — any register from any poll, or computed tags — into a floating window over the workspace (👁 Watch in the toolbar).
- Big live values in engineering units, coloured by the rule tree (alarm fg/bg carry over from the table row), session min / max per card, quality and «no link» markers.
- The pinned set is stored in the project (shared with Save/Open); the window position is remembered per workstation. Double-click a card to give it a custom caption, ✕ unpins, ⟲ resets min/max, clicking a value jumps to the table row.
🧪 Slave simulator & typed values (v1.3)
📖 Full app tutorial (RU):
docs/guide-app-ru.md— connections, polls, rules (incl. named word bits), tags, mimic, archive, OPC bridge.📖 Full simulator guide (RU):
docs/guide-slave-ru.md— quick start, connecting masters, data types, dec/hex/bin display, recipes and troubleshooting. An English version is planned.
- Both sides of the wire in one app. The new Slave simulator tab serves coils / discrete / holding / input registers over Modbus TCP, RTU-over-TCP and, since v1.4, a physical serial line (USB-RS485 adapter: port, baud, parity, data/stop bits) — point any master at
localhost:10502, wire it to an RS-485 bus, or poll it with mbSCADA itself. - Live register grid with a typed view (u16 / i16 / hex / u32 / i32 / float CDAB·ABCD): edit a cell and the slave’s data model changes immediately; checkboxes for bit areas; the raw register bits are shown next to the typed value.
- Auto-generation (sine / ramp / noise with amplitude, base and period) animates the selected range, so alarm rules, trends and mimics have something realistic to chew on.
- Typed values everywhere. Every poll carries a data type — the quick selector sits right on the table card (one click after the
.mbpimport). Typed write modals encode the value into registers for you: float → two words with the right word order, i16 → two’s complement, hex/bin inputs accepted as0x…/0b…. - Per-cell display: right-click any value to cycle dec → hex → bin (per row), or set the default for the whole poll.
- UI overhaul under the hood: tables, mimic and the journal now update in place instead of rebuilding the DOM every 300 ms — no more lag and no more double-clicks torn apart by a re-render.
🗺 SCADA mode (mimic diagrams)
![]() |
Editor with lamps, gauges, bars, live values and toggle-write buttons bound to registers — every widget configurable by double-click… plus the alarm panel and traffic log on the right |
Modbus Poll has no SCADA mode. That is the point of mbSCADA.
🧮 Computed tags, journal, archive & diagnostics (v1.1)
- Computed (virtual) tags: a safe arithmetic evaluator in the engine —
{tag} references,p<poll>:<addr>aliases,+ - * / % ^, functionsmin / max / avg / abs / sqrt / round / floor / ceil / pow. Results appear in their own table above the polls (with units and error messages in place), and are archived to CSV together with the live tags. - Event journal to file: the engine appends every RX / WR / ERR / SYS line (with full timestamps) to the log file configured in «Журнал и архив» — a permanent record of the exchange alongside the in-app log.
- Configurable CSV archive: change-only mode (a row when a value changes) or «all tags by period» mode; the file is stored in the project and automatically resumes on start.
- Diagnostics panel: per connection — TX/RX, errors/timeouts, reconnects, last/avg turnaround, time since the last successful exchange, last error; per poll — ok/err counters and its own turnaround.
🌉 OPC UA bridge (mb-opc, v1.6.0)
The same project file, served to any OPC UA client — SCADA masters, historians, MES. The bridge polls Modbus with the same engine as the app and exposes every tag over opc.tcp:
mb-opc --project my-plant.json --listen 0.0.0.0:4840
- Browse tree
mbSCADA/<poll>/<row label>,Computed/<tag>,Status/<connection>/online|tx|errors. - Bit polls (FC1/FC2) →
Boolean, everything else →Doublein engineering units (×mult ÷div +offsetapplied). - Row quality becomes OPC UA status: good →
Good, not read yet →Uncertain (last usable), error →Bad (comm failure); source timestamps come from the engine. - Read coalescing: neighbouring polls on the same connection merge into wider transactions (125-register / 2000-bit protocol limits respected) — fewer Modbus round-trips per cycle.
- Write-back: holding-register and coil tags are writable from the OPC UA side — a client
writeis unscaled (×mult ÷div +offsetreversed), split into words in the tag's byte order and sent to the device as FC 05 (coil) / FC 06 (register) / FC 16 (32/64-bit multi-register). Input areas (FC2/FC4) are read-only by design. - Node ids are stable (
ns=1;s=p<poll_id>:<addr>(the bridge namespace; its index is whatregister_namespaceassigns — typically 1)), so clients subscribe by id. Security policy is None/anonymous — keep the bridge on a trusted network. - Ships as a standalone binary (
mb-opc-*in every release) — next to the app or headless on a gateway.
💾 Save as Modbus Poll (.mbp, v1.6.0)
Every table card has a .mbp ↓ button — the table goes back to Modbus Poll:
- Imported from a
.mbpand the file is still on disk? The export is byte-exact: the document is re-parsed losslessly, current aliases are edited into their own row markers, and everything else — header, colours, settings blob, v5 IP string — stays byte-for-byte as Modbus Poll wrote it. - Otherwise (polls created in the app, or a moved/deleted file) a canonical v4 table is generated: function code, notation-encoded address, aliases, scan period, slave ID.
- Not stored in the generated file (
.mbphas no fields for them): scaling (mult/div/offset), units, alarms, computed tags — those live in the app's project JSON.
🔄 Auto-update (v1.7.0)
The app checks for a new release on start (silently — a banner appears only when one exists) and updates with one click:
- Official Tauri updater: manifest
latest.jsonin GitHub Releases, every artifact is minisign-signed (public key intauri.conf.json, private key in CI secrets). A tampered artifact is rejected, not installed. - Nothing installs silently: the banner says
Version {v} is available — install now?, you decide. - Works for installer-based and portable installs; on Linux the updater path is AppImage (
.deb/.rpmusers update through the package manager). - Bootstrap: v1.6.0 was built before the updater existed, so once — manually — install v1.7.0; every later release arrives automatically.
🤝 Modbus Poll compatibility
- Import of
.mbp(single window) and.mbw(workspace with the window list) — one by one or by folder. - Byte-exact round-trip (
mbp_doc): the file is segmented (head/ row records / closing marker) and reassembled bit-for-bit; editing an alias touches nothing else. Verified byte-exactly against a private real-file corpus produced by Modbus Poll 10.5 (7 files, RU aliases, UTF‑16 markers); CI runs the same test on a public synthetic corpus. - Format, multiplier, address base, aliases and colours carry over into polls; imported polls bind to your own connections (host:port match first, else the first one) — no connections are silently pulled from the files. Each connection carries a default slave ID that its polls inherit (a poll may still override it).
📐 Real corpus layout (reverse-engineered)
[head] magic v4=7000 (v5=10010), IP marker (v5), [144][func][addr][qty]
[row record] × qty marker FF FE FF + len + UTF-16LE alias → PAD 55555555
+ 6× colour u32 (FF000000 AVG) + zeros
[last row + settings] the last row's gap holds the settings blob & tail
[period][slave][1][0][0][…]
[closing marker] final empty marker FF FE FF 00 + trailer bytes
🚀 Getting started
Install
Download an installer for your OS from Releases (see the table above), install — and run mbSCADA.
Build from source
Requirements: Rust 1.85+, Windows (WebView2 is preinstalled on Win10/11), or Linux with libudev-dev pkg-config libwebkit2gtk-4.1-dev for GUI work.
git clone https://github.com/kostyk348/mbscada-rs.git cd mbscada-rs cargo test # 68 engine/proto/format tests # demo slave (no hardware needed): serves registers on 127.0.0.1:502 cargo run -p mb-sim --example demo_server -- 502 # the app (Tauri 2), raw binary cargo build --release -p mbscada # → target/release/mbscada # or full installers for your current OS cargo install tauri-cli --version '^2' cargo tauri build
Launch mbSCADA, «Импорт папки…» your .mbp folder and hit Старт — real Modbus Poll windows appear as polls and start flowing.
🏗 Architecture
┌────────────────────────────────────────────────────────────────────┐
│ Tauri 2 desktop shell (Rust) │
│ src-tauri: dialogs, project JSON, CSV append, engine restarts │
├────────────────────────────────────────────────────────────────────┤
│ UI (vanilla JS) │
│ tables · rules (32) · SCADA editor · watch window · traffic log │
├────────────────────────────────────────────────────────────────────┤
│ crates/ │
│ mb-proto PDU encode/decode · MBAP · RTU+CRC · ASCII ':'+LRC │
│ mb-format .mbp/.mbw parser → lossless MbpDoc → semantic Table │
│ mb-engine multithreaded poller: TCP · RTU-serial · RtuOverTcp │
│ · Ascii-serial · AsciiOverTcp, rules, alarms, trends │
│ mb-sim slave simulator (+ demo_server example) │
│ mb-opc OPC UA bridge: project JSON → opc.tcp tag server │
│ mb-opc OPC UA bridge: project JSON → opc.tcp tag server │
└────────────────────────────────────────────────────────────────────┘
🗺 Roadmap
- ✅ Modbus/TCP, RTU, RTU-over-TCP transports with per-connection traffic log (v0.1)
- ✅ Import
.mbp/.mbwby file and by folder (v0.1) - ✅ 32-branch styled rules + dynamic row text — UI and engine (v0.2)
- ✅ Display formats through 64-bit: hex32 / ascii16 / u16‑swapped / u64 / i64 / f64 (v0.3)
- ✅ Byte-exact
.mbpround-trip on a real corpus (v0.4) - ✅ Modbus ASCII framing + ASCII serial & over-TCP transports (v0.4)
- ✅ Per-row sparklines + CSV value log (v0.4)
- ✅ In-place editing of connections / polls / rules; per-connection default slave ID; imports bound to your own connections (v1.0)
- ✅ Prebuilt release bundles: Windows x64, Linux x86_64 + aarch64, macOS Intel + Apple Silicon (v1.0)
- ✅ Alarm side panel (ack, history, sound, jump-to-row) + SCADA gauge / toggle-write widgets (v1.1)
- ✅ One-click RU/EN UI switch, bilingual docs, refreshed screenshots (v1.1)
- ✅ Computed tags: safe expression engine + own table + editor (v1.1)
- ✅ Engine event journal to a log file; configurable CSV historian (change-only / interval) that resumes on start (v1.1)
- ✅ Diagnostics panel: per-poll ok/err stats, reconnect counters, last-success age (v1.1)
- ✅ Fix: SCADA gauge colored arc overflowed the widget border (v1.1)
- ✅ Fix: SCADA gauge arc swept the wrong way above half-scale — SVG large-arc flag on a ≤180° sweep (v1.5.1)
- ✅ Production-grade alarm panel: colored severity chips (CRIT/HIGH/LOW) next to the value, severity-first sorting, re-alert on level escalation, unacknowledged-critical dot pulse, info level is silent (v1.5.2)
- ✅ Fix: Windows shortcut kept the old icon after an in-place upgrade — the installer now flushes the shell icon cache (SHChangeNotify via an NSIS hook) (v1.5.2)
- ✅ OPC UA bridge
mb-opc: serves an mbSCADA project over opc.tcp — every poll row and computed tag as a variable with quality and source timestamps, connection status (online/tx/errors) (v1.6.0) - ✅ Poll coalescing: neighbouring polls merge into wider Modbus transactions — fewer round-trips per cycle, protocol-limit aware, grids checked for 32-bit formats (v1.6.0)
- ✅ Save as Modbus Poll:
.mbp ↓on every table card — byte-exact for imported tables (only alias markers rebuilt), canonical v4 generation otherwise (v1.6.0) - ✅ Auto-update: signed Tauri updater, silent check on start, one-click install (v1.7.0)
- ✅ Fix: CI got
timeout-minutes: 30— a hanging e2e can no longer burn the six-hour job limit (v1.6.0) - ⚠ Attempted fix, reverted: auto-generating the OPC UA certificate deadlocks the first tag read after a successful session — see «Known issues» (v1.6.0)
- ✅ Fix: e2e write-back assertion rebuilt the u32 in the wrong word order (v1.6.0)
- ⬜ Dark/light UI theme
- ⬜ Search box on the live tables (filter rows by label/value)
- ⬜ Per-row trend window (bigger than a sparkline)
- ⬜ OPC UA bridge: signed/encrypted endpoints (write-through is already in)
- ⬜ Spike: egui frontend on a branch — evaluate against the Tauri UI, no decision yet
💡 Ideas worth building next
A shortlist of what would move the project most (roughly in order):
- Trend window per row — a proper chart with zoom/pan on top of the sparkline ring buffer; the engine already keeps history, only the UI is missing.
- OPC UA security — Basic256Sha256 endpoints with user/password tokens; the bridge now has a certificate to build on.
- Lua/expr scripting for computed tags — today the expression engine is read-only math; user-defined functions would open SCADA logic (blocks, counters, hysteresis).
- Alarm history export + archiving to the CSV historian — alarms exist in the panel but not in the log files.
- Import from hardware — device scan (FC43/14 device ID) and auto-generation of a poll skeleton from a PLC's address map.
- Headless service mode for the app engine —
mbscada --service project.json: the desktop engine andmb-opcconverge into one daemon with metrics. - egui spike — one vertical slice (live table) rebuilt in egui on a
spike/eguibranch to compare memory, latency and packaging; no migration decision until the spike numbers exist.
⁇ Known issues
- OPC UA bridge e2e hangs on the handshake.
crates/mb-opc/tests/bridge_it.rsis#[ignore]d in CI: without an application certificate the client sometimes retriesCreateSessionforever, and with certificates on both sides it deadlocks on the first tag read. The bridge itself works with real clients; the in-process e2e needs a deterministic handshake. Run it on demand withcargo test -p mb-opc --test bridge_it -- --ignored --nocapture.
⁇ FAQ
Is this a Modbus Poll rip-off?
No. This is a clean-room implementation: the wire protocol is public spec, and the .mbp layout was learned from byte-level analysis of files produced by Modbus Poll 10.5 — no proprietary source code was touched.
What "byte-exact round-trip" means for me? Your Modbus Poll files go in, everything else comes back identical. mbSCADA can edit aliases without regenerating the whole file, so unedited bytes stay exactly as Modbus Poll wrote them.
Does it talk to my devices today? TCP / RTU / RTU-over-TCP are production paths with integration tests. ASCII framing and its serial / over-TCP transports are implemented and unit-tested; wire-side integration testing on real devices is on the roadmap.
Why Rust?
One executable, no runtime, memory-safe poller — and the whole engine is testable headlessly (see cargo test).
🤝 Contributing
Issues and PRs welcome. The engine is test-first: crates/mb-engine, crates/mb-format / crates/mb-proto all have unit suites covering Tauri-free paths — start there.
Contributing
- Good first issues — scoped tasks with the acceptance criteria written down, sized for one sitting.
- Discussions — questions, ideas and "how do I…"; issues are for bugs.
- CONTRIBUTING.md — how to build, test and submit a change.
- SECURITY.md — private reporting for vulnerabilities (never a public issue).
Pull requests are reviewed against one rule: the description must say what problem it solves and how it was verified — a CI link or a pasted command output.